Pressure switch MDR 1
Downloads
Technical specifications
- Type series
- MDR 1
- Medium
- Air
- Voltage type
- Alternating current (AC) – single-phase
- Type
- Electro-mechanical
- Voltage
- ≤ 250 V
- Contact function
- 2 NC contacts
- Gold-plated contacts
- no
- Pressure adjustment
- Pressure difference adjustment (standard)
- Pressure range (bar)
- ≤ 11 Bar
- Pressure coupling
G1/4" aluminium female thread (main pressure coupling G1/4", pressure connector material = die-cast aluminium)
F4 1/4" aluminium female thread (main pressure coupling G1/4", 3 side outlets G1/4", pressure connector material = die-cast aluminium)
F4 3/8" aluminium female thread (main pressure coupling G3/8", 3 side outlets G1/4", pressure connector material = die-cast aluminium)
F4 1/4" NPT (main pressure coupling 1/4", 3 side outlets 1/4" NPT (National Pipe Thread) female thread, pressure connector material = die-cast aluminium)
- Overload relay
- not possible
- Cable entry gland
with PG 11 Z/ZK
- Relief valve
- with AEV (accessory EV)
- Mechanical On/Off (EA)
- with/without On/Off
- Rated frequency
- 50 Hz / 60 Hz
- Rated operating current (Ie)
20 A
- max. media temperature
80°C
- Motor switching capacity
- 2,5 kW
- Protection class
- IP 44
Applications
Certicates & Permits
At a glance
- High-performance pressure switch for AC voltage
- for compressors
- Pressure connector material = die-cast aluminium
- with start-up relief valve (AEV)
- Oper. hours counter (optional)
- Motor switching capacity 2.5 kW
- max. cut-out pressure 11 bar
- 2-pole (NC)
To determine the pump or compressor run-time, the MDR 1 can be fitted/retro-fitted with an (optional) operating hours counter. The operating hours counter is available as a kit, and can be mounted to the cover in 4 different positions at 90° intervals. This ensures optimum readability. The kit consists of an operating hours counter for 230 V, and a perforated MDR 1 cover with/without On/Off switch. The MDR 1 is fitted as standard with the possibility for pressure difference adjustment. Two adjusting screws permit switching point and hysteresis to be adjusted, whereby the cut-out point is first adjusted via the main pressure spring and then the cut-in point via the pressure difference setting. By selecting a pair of values for cut-in and cut-out pressures, an intersection point is determined in the diagram. If the point lies within the shaded area, this pair of values can be adjusted on the pressure switch. If the point lies outside the shaded area, this pair of values cannot be adjusted on the pressure switch. Example: MDR 1/11 with pressure difference adjustment. With a selected cut-in pressure of 4 bar, the cut-out pressure can be specified and adjusted between 5, 4 and 8 bar using the pressure difference adjustment.