Pressure switch MDR 2i
Downloads
Technical specifications
- Medium
- Air, Water
- Voltage type
- Alternating current (AC) – single-phase
- Type
- Electronic
- Voltage
- ≤ 250 V
- Contact function
- 2 NC contacts
- Gold-plated contacts
- no
- Pressure adjustment
- Pressure difference adjustment (standard)
- Pressure range (bar)
- ≤ 16 Bar
- Pressure coupling
G1/4" female thread or flange connection = die-cast aluminium
- Overload relay
- not possible
- Cable entry gland
without (accessory M20)
- Relief valve
- without (accessory EV, AEV)
- Rated frequency
- 50 Hz / 60 Hz
- Rated operating current (Ie)
16 A
- max. media temperature
70°C
- Motor switching capacity
- 2,2 kW
- Protection class
- IP 54, IP 41
Applications
Certicates & Permits
At a glance
- AC version
- Voltage ≤250 V
- Switching function "2 x NC"
- Pressure ranges ≤16 bar
- integral pressure relief valve (optional)
- coupling for external pressure relief valve
- Two-point control (switching point / switch-back point)
- Die-cast aluminium flange
The two-point control permits precise and convenient programming of the switching functions (switching point / switch-back point), adjustable in bar or psi (accuracy 0.1 bar / 1 psi). Because of the wide range of pressure switch versions, please contact us if you have questions on a special application or have technical requirements. As a manufacturer of pressure switches and controls, we offer a wide range of services, including standard and customer-specific solutions for individual applications.